Refer to our Building Legislation Table for further information on the building control process. Disability Access Toilet Facilities Generally a unisex accessible toilet must be provided on every storey where there are toilets. Click here to read the Terms of Service. Class 1b and 2 changes under the BCA.

Uploader: Vudogore
Date Added: 26 June 2007
File Size: 41.79 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 77967
Price: Free* [*Free Regsitration Required]





In buildings with a total floor area of more than m 2a pedestrian entrance that is not accessible for people with disabilities must not be located more than 50m from an accessible pedestrian entrance.

Fire isolated stairways must have luminance contrast nosing strips at each tread. Click here to read the Terms of Service Log In.

Accessways must have passing spaces and turning spaces at intervals and locations in accordance with D3. Increased wheelchair requirements in class 9b assembly buildings in accordance with clause D3. Carpet pile heights and thickness limitations under clause D3.

Class 1b and 2 changes under the BCA. Increased and improved Braille, tactile and directional signage requirements.

The width of car parking spaces have been reduced to 2. The introduction of a wider range of passenger lift options, with limitations on use under clause E3. Access requirements for Public Transport Buildings.

Where a doorway has multiple leaves except an automatic opening door one of ss leaves must have a clear opening width of not less than mm. HENDRY building surveying consultants can provide clients with an existing building disability access appraisal prior to applying for a building permit.

Disability Access: AS - - Hendry

Click here to read the Terms of Service. Every az and stairway, other than fire isolated stairways must comply with clause 10 and 11 of AS Disability Access Toilet Facilities Generally a unisex accessible toilet must be provided on every storey where there are toilets.

Increased clear opening width of doorways from mm to now mm. A back rest is required at the accessible toilet and the circulation spaces and clearances have increased in accessible toilets. The dimensions, grab rails, doors and signage requirements for people with ambulant disabilities are provided in section 16 of AS Refer to our list of Referenced Disability Access Standards for further information on disability access requirements.

Referenced Disability Access Standards Refer to our list of Referenced Disability Access Standards for further information on disability access requirements.

Standards Catalogue

An exemption to not require access in accordance with AS Class 3 accommodation buildings must have accessible rooms and one for each common area. Some of the major Disability Discrimination Act changes, implications and concessions applicable to buildings are as follows.

Tactile indicators previously only had to be provided at stairs, ramps and escalators used by the public, now they must be provided at all stairs other than fire isolated stairwaysramps and escalators for public and xs, etc.

Left and right handed toilet facilities for people with disabilities must be provided where there is more than one accessible toilet provided. An ambulant accessible toilet, in addition to a unisex accessible toilet, must now be provided. Refer to our Building Legislation Table for further information on az building control process.

Building Legislation Table Refer to our Building Legislation Table for further information on the building control process.